• YS-18
  • YS-209

RAM-100 Area Monitor with Optional Detector

Short Description:

RAM-100 Area Monitor is intended for strong optical and audible alarm signalling when the thresholds of the measured parameters have been exceeded. The unit is controlled by a host system.


  • :
  • Product Detail

    Product Tags

    Applications

    Nuclear Medicine
    Nuclear Industry
     
    Nuclear Power Station
     
    Renewable Resources
     
    Scientific Research Institute
     

    Product Features

    Local display of measurements with up to 16 intelligent dose rate probes
    Adjustable alarm levels
    LCD display
     
    Connect different detectors to detect X , γ, β and n
    Analog output (option)
    Digital bit input/output for monitoring of conditions and alarms
    Connection to a local PC via RJ45 interface
     
    Incorporation in measuring networks via RS485 interface
    Strong audible and visible signalling
     
    Normal status

    Normal Status

    Alarm status

    Alarm Status

    Technical Specifications

     
     Display
    Display
    5 inches LCD
    Measurement unit
    nGy/h, μGy/h, mGy/h, Gy/h, nSv/h, μSv/h, mSv/h, Sv/h, CPS
    Status display
    Normal, Offline, Alarm, Overload
    Alarm
    Alarm function
    Adjustable alarm levels
    Fault alarm
    when the dose rate exceeds the intrusion value
    Alarm modes
    Strong audible and visible signalling
    Function
    Local display of measurements
    Local settings
    Digital bit input/output for monitoring of conditions and alarms
    Connection
    Maximal number of connections
    16 intelligent dose rate probes
    Analog
    3-way output
    Dose rate probes communication
    RS485
    Connection to a local PC
    RJ45
    General
    Storage temperature
    -30℃ to +60℃
    Operation temperature
    -20℃ to +55℃
    Humidity
    0- 95%
    Size
    332×308×97mm(13” x 12.1” x 3.8”)
    Weight
    3.8kg (2.8lb)
    Power
     AC 110~260V 50Hz,0.5A

    Probe Selection

     
    Model
    Type
    Detector
    Measuring Range
    Energy Range
    Sensitivity
    RAM-G
    X、γ
    GM tube
    0.1μSv/h ~ 100mSv/h
    40keV ~ 3MeV
    1.8 cps / (μSv/h )
    RAM-2G
    X、γ
    GM tube
    0.1μSv/h ~ 10Sv/h
    40keV ~ 3MeV
    Low range: 1.8cps/(μSv/h )
    High range: 26cps /(mSv/h)
    RAM-10GM/1
    X、γ
    GM tube
    0.1μSv/h ~ 100mSv/h
    40keV ~ 3MeV
    1.8 cps / (μSv/h )
    RAM-10GM/2
    X、γ
    GM tube
    0.1μSv/h ~ 10Sv/h
    40keV ~ 3MeV
    Low range: 1.8cps/(μSv/h )
    High range: 26cps /(mSv/h)
    RAM-G/16
    X、γ
    GM tube
    0.01μSv/h ~ 10mSv/h
    40keV ~ 3MeV
    90cps/(10μSv/h)
    RAM-2G/16
    X、γ
    GM tube
    0.01μSv/h ~ 10Sv/h
    40keV ~ 3MeV
    Low range: 90cps/(10μSv/h )
    High range: 1.7cps /(μSv/h)
    RAM-N
    n
    He-3
    0.1μSv/h ~ 100mSv/h
    0.025 eV ~ 14MeV
    3cps/(μSv/h)

     

    Configuration List


  • Previous:
  • Next:

  • Related products